LIQUID-BASED PAP, DIAGNOSTIC

Test ID
1025750201
Test Name
LIQUID-BASED PAP, DIAGNOSTIC
Test Report Name
Liquid-based pap smear
Test Synonyms
LABPAPD|PAP
Collection Requirements
No lubricants should be used. Preferably, collection should take place two weeks after the first day of the menstrual cycle. A cotton tip applicator may not be used; instead use a plastic spatula and cervical brush, or a plastic broom. Label the Thin Prep Pap Test vial (PreservCyt Solution) with the patient's full name & one other identifier prior to collection. After collection, immediately immerse the collection instrument into the vial and dislodge the cells by: ~swirling the spatula vigorously 10 times ~rotating the brush against the wall of the vial 10 times ~pushing the broom against the bottom of the vial, forcing the bristle apart, 10 times. Then swirl the broom vigorously another 10 times. Discard the collection device-Do Not Leave it in the Vial.
Shipping and Handling Instructions
Tightly seal the vial and place it in a specimen bag for transport to the laboratory. Specimen may be transported at room temperature.
Notes

Last Edit Instant
3/13/2023 10:11 AM
Last Edit Reason
TRE Updated via Data Courier
Test Information

Orderable

Procedure NameProcedure Code/IDProcedure Display NameMPI Type^MPI IDDefault Specimen TypeOrderable?Performable?
LIQUID PAP DIAGNOSTICLABPAPDCyto Pap, Liquid Vial-DiagnosticSTAREAP^404102|EDIRESEAP^LABPAPDPap, Thin PrepYesYes
PAP DIAGNOSTIC AND HPV WITH GENOTYPINGLABPAPDHPVPAP, Diagnostic and HPV W/ GenotypePap, Thin PrepYesNo